Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 16(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38475326

RESUMO

BACKGROUND: Theophylline (THN), a bronchodilator with potential applications in emerging conditions like COVID-19, requires a controlled-release delivery system due to its narrow therapeutic range and short half-life. This need is particularly crucial as some existing formulations demonstrate impaired functionality. This study aims to develop a new 12-h controlled-release matrix system (CRMS) in the form of a capsule to optimize dosing intervals. METHODS: CRMSs were developed using varying proportions of poloxamer 407 (P-407), stearyl alcohol (STA), and hydroxypropyl methylcellulose (HPMC) through the fusion technique. Their in vitro dissolution profiles were then compared with an FDA-approved THN drug across different pH media. The candidate formulation underwent characterization using X-ray diffraction, scanning electron microscopy, Fourier transform infrared spectroscopy, differential scanning calorimetry, and thermogravimetric analysis. Additionally, a comprehensive stability study was conducted. RESULTS: In vitro studies showed that adjusting the concentrations of excipients effectively controlled drug release. Notably, the CRMS formulation 15 (CRMS-F15), which was composed of 30% P-407, 30% STA, and 10% HPMC, closely matched the 12 h controlled-release profile of an FDA-approved drug across various pH media. Characterization techniques verified the successful dispersion of the drug within the matrix. Furthermore, CRMS-F15 maintained a consistent controlled drug release and demonstrated stability under a range of storage conditions. CONCLUSIONS: The newly developed CRMS-F15 achieved a 12 h controlled release, comparable to its FDA-approved counterpart.

2.
Pharmaceuticals (Basel) ; 17(3)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38543057

RESUMO

BACKGROUND: Drug release from controlled release delivery systems is influenced by various factors, including the polymer's grade and the drug's hydration form. This study aimed to investigate the impact of these factors on the controlled release of theophylline (THN). This research compares the monohydrate form found in branded products with the anhydrous form in generic equivalents, each formulated with different polymer grades. METHODS: Quality control assessment was conducted alongside in vitro evaluation, complemented by various analytical techniques such as X-ray diffraction (XRD) and scanning electron microscopy (SEM). Additionally, thermal analyses using differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) were employed. RESULTS: Quality control assessments demonstrated that the generic tablets exhibited lower average weight and resistance force compared to the branded ones. In vitro tests revealed that generic tablets released contents within 120 min, compared to 720 min for the branded counterpart. Characterization using XRD and SEM identified disparities in crystallinity and particle distribution between the three samples. Additionally, the thermal analysis indicated consistent endothermic peaks across all samples, albeit with minor variations in heat flow and decomposition temperatures between the two products. CONCLUSIONS: This study demonstrated that variations in polymer grade and hydration form significantly impact THN release.

3.
Pharmaceuticals (Basel) ; 17(3)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38543101

RESUMO

Cancer continues to pose one of the most critical challenges in global healthcare. Despite the wide array of existing cancer drugs, the primary obstacle remains in selectively targeting and eliminating cancer cells while minimizing damage to healthy ones, thereby reducing treatment side effects. The revolutionary approach of utilizing nanomaterials for delivering cancer therapeutic agents has significantly enhanced the efficacy and safety of chemotherapeutic drugs. This crucial shift is attributed to the unique properties of nanomaterials, enabling nanocarriers to transport therapeutic agents to tumor sites in both passive and active modes, while minimizing drug elimination from delivery systems. Furthermore, these nanocarriers can be designed to respond to internal or external stimuli, thus facilitating controlled drug release. However, the production of nanomedications for cancer therapy encounters various challenges that can impede progress in this field. This review aims to provide a comprehensive overview of the current state of nanomedication in cancer treatment. It explores a variety of nanomaterials, focusing on their unique properties that are crucial for overcoming the limitations of conventional chemotherapy. Additionally, the review delves into the properties and functionalities of nanocarriers, highlighting their significant impact on the evolution of nanomedicine. It also critically assesses recent advancements in drug delivery systems, covering a range of innovative delivery methodologies. Finally, the review succinctly addresses the challenges encountered in developing nanomedications, offering insightful perspectives to guide future research in this field.

4.
Pharmaceuticals (Basel) ; 16(4)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37111296

RESUMO

Generic medications are bioequivalent to brand-name medications, but the quality and purity of generic medications are still debatable. The aim of this study was to compare the generic product of metformin (MET) to its branded counterpart using pure MET powder as a reference. Quality control tablet assessment and in vitro evaluation of drug release were carried out in various pH media. Additionally, several analytical methods and thermal techniques were used, namely differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier-transform infrared (FTIR), and confocal Raman microscopy. The results showed a significant difference between the two products. In terms of friability assessment, mean resistance force, and tablet disintegration, the generic MET product showed significant weight loss, higher mean resistance force, longer disintegration time, and a slower rate of drug release. In addition, DSC and TGA showed that the generic product had the lowest melting point and the least weight loss compared to the branded product and pure powder. XRD and SEM demonstrated some changes in the crystallinity structure of the molecule particles for the generic product. Additionally, FTIR and confocal Raman revealed the same peaks and band shifts in all samples, but with differences in the intensity for the generic tablet only. The observed differences could be due to the use of different excipients in the generic product. The possibility of forming a eutectic mixture between the polymeric excipient and metformin in the generic tablet was presumed, which might be attributed to alterations in the physicochemical properties of the drug molecule in the generic product. In conclusion, using different excipients might have a significant effect on the physicochemical properties of drugs in generic formulations, leading to significant changes in drug release behavior.

5.
F1000Res ; 12: 1325, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38596002

RESUMO

Background: Enteric coating films in acidic labile tablets protect the drug molecule from the acidic environment of the stomach. However, variations in the excipients used in the coating formulation may affect their ability to provide adequate protection. This study is the first to investigate the potential effects of coating materials on the protective functionality of enteric coating films for pantoprazole (PNZ) generic tablets after their recall from the market. Methods: A comparative analysis was conducted between generic and branded PNZ products, using pure drug powder for identification. The in vitro release of the drug was evaluated in different pH media. The study also utilized various analytical and thermal techniques, including differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier-transform infrared (FTIR), and confocal Raman microscopy. Results: The in vitro assessment results revealed significant variations in the release profile for the generic product in acidic media at 120 min. DSC and TGA thermal profile analyses showed slight variation between the two products. XRD analysis exhibited a noticeable difference in peak intensity for the generic sample, while SEM revealed smaller particle sizes in the generic product. The obtained spectra profile for the generic product displayed significant variation in peaks and band intensity, possibly due to impurities. These findings suggest that the excipients used in the enteric coating film of the generic product may have affected its protective functionality, leading to premature drug release in acidic media. Additionally, the presence of polysorbate 80 (P-80) in the brand product might improve the properties of the enteric coating film due to its multi-functionality. Conclusions: In conclusion, the excipients used in the brand product demonstrated superior functionality in effectively protecting the drug molecule from acidic media through the enteric coating film, as compared to the generic version.


Assuntos
Excipientes , Estômago , Pantoprazol , Liberação Controlada de Fármacos , Excipientes/química , Solubilidade , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...